After-sales Service: | Yes |
---|---|
Warranty: | 5 Years |
Nature of Source Flow: | Active Inverter |
Phase: | Three |
Output Power: | 15kw |
Certification: | SAA, CE, ROHS, ISO9001, TUV CQC SAA |
Customization: |
---|
Suppliers with verified business licenses
Type designation
|
SG15KTL-M
|
Input (DC)
|
|
Max. PV input voltage
|
1100 V
|
Min. PV input voltage / Startup input voltage
|
200 V / 250 V
|
Nominal PV input voltage
|
600 V
|
MPP voltage range
|
380 V - 850 V
|
MPP voltage range for nominal power
|
550V - 850 V
|
No. of independent MPP inputs
|
2
|
Max. number of PV strings per MPPT
|
2
|
Max. PV input current
|
44 A (22 A / 22 A)
|
Max. DC short-circuit current
|
60 A (30 A / 30 A )
|
Output (AC)
|
|
AC output power
|
16.5 kVA @ 35 ºC / 15 kVA @ 45 ºC
|
Max. AC output current
|
24.0 A
|
Nominal AC voltage
|
3 / N / PE, 230 / 400 V
|
AC voltage range
|
270 V - 480 V
|
Nominal grid frequency / Grid frequency range
|
50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
|
THD
|
< 3 % (at nominal power)
|
DC current injection
|
< 0.5 % In
|
Power factor at nominal power / Adjustable power factor
|
> 0.99 / 0.8 leading - 0.8 lagging
|
Feed-in phases / connection phases
|
3 / 3
|
Efficiency
|
|
Max. efficiency
|
98.6 %
|
Euro. efficiency
|
98.3 %
|
Protection
|
|
DC reverse connection protection
|
Yes
|
AC short circuit protection
|
Yes
|
Leakage current protection
|
Yes
|
Grid monitoring
|
Yes
|
Ground fault monitoring
|
Yes
|
DC switch
|
Yes (not available for Australia)
|
AC switch
|
No
|
PV String current monitoring
|
Yes
|
PID recovery function
|
Yes
|
Overvoltage protection
|
DC Type II / AC Type II
|
General Data
|
|
Dimensions (W*H*D)
|
370*485*210 mm
|
Weight
|
24 kg
|
Isolation method
|
Transformerless
|
Ingress protection rating
|
IP65
|
Night power consumption
|
< 1 W
|
Operating ambient temperature range
|
-25 to 60 ºC (> 45 ºC derating)
|
Allowable relative humidity range (non-condensing)
|
0 - 100 %
|
Cooling method
|
Smart forced air cooling
|
Max. operating altitude
|
4000 m (> 3000 m derating)
|
Display
|
LED, Bluetooth+APP
|
Communication
|
RS485 / Optional: Wi-Fi, Ethernet
|
DC connection type
|
MC4 (Max. 6 mm² )
|
AC connection type
|
OT / DT terminal (Max. 70 mm²)
|
Compliance
|
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018,
VDE-AR-N 4120:2018, IEC 61000-6-3, EN 50549, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA |
Grid Support
|
Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control
|