Customization: | Available |
---|---|
Warranty: | 10years |
Type: | DC/AC Inverters |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type designation
|
SG33CX
|
SG40CX
|
SG50CX
|
Input (DC)
|
|||
Max. PV input voltage
|
1100 V
|
||
Min. PV input voltage
|
200 V
|
||
Startup input voltage
|
250 V
|
|
|
Nominal PV input voltage
|
585 V
|
||
MPP voltage range
|
200 - 1000 V
|
||
MPP voltage range for nominal power
|
550V - 850 V
|
||
No. of independent MPP inputs
|
3
|
4
|
5
|
Max. number of PV strings per MPPT
|
2
|
||
Max. PV input current
|
78A
|
104A
|
130A
|
Max. DC short-circuit current
|
120A
|
160A
|
200A
|
Output (AC)
|
|||
AC output power
|
33kw
|
40kw
|
50kw
|
Max. AC output current
|
55.2 A
|
66.9 A
|
83.6 A
|
Nominal AC voltage
|
3 / N / PE, 230/400 V
|
||
AC voltage range
|
312 - 528 V
|
||
Nominal grid frequency
Grid frequency range THD
|
50 Hz / 45 - 55 Hz, 60 Hz / 55 - 65 Hz
< 3 % (at nominal power) |
||
DC current injection
|
< 0.5 % In
|
||
Power factor at nominal power
|
> 0.99
|
||
Adjustable power factor
|
0.8 leading - 0.8 lagging
|
||
Feed-in phases / connection phases
|
3 / 3
|
||
Efficiency
|
|
|
|
Max. efficiency
|
98.6%
|
98.6%
|
98.7%
|
Euro. efficiency
|
98.3 %
|
98.3 %
|
98.4%
|
Protection
|
|
|
|
DC reverse connection protection
|
Yes
|
||
AC short circuit protection
|
Yes
|
||
Leakage current protection
|
Yes
|
||
Grid monitoring
|
Yes
|
||
Ground fault monitoring
|
Yes
|
||
DC switch
|
Yes
|
||
PV String current monitoring
|
Yes
|
||
PID recovery function
|
Yes
|
||
Overvoltage protection
|
DC Type II / AC Type II
|
||
General Data
|
|
|
|
Dimensions (W*H*D)
|
702*595*310mm
|
782*645*310mm
|
782*645*310mm
|
Weight
|
50KG
|
58KG
|
62KG
|
Isolation method
|
Transformerless
|
||
Ingress protection rating
|
IP66
|
||
Night power consumption
|
≤2 W
|
||
Operating ambient temperature range
|
-30 to 60 ºC
|
||
Allowable relative humidity range (non-condensing)
|
0 - 100 %
|
||
Cooling method
|
Smart forced air cooling
|
||
Max. operating altitude
|
4000 m (> 3000 m derating)
|
||
Communication
|
RS485 / Optional: Wi-Fi, Ethernet
|
||
DC connection type
|
MC4 (Max. 6 mm² )
|
||
AC connection type
|
OT or DT terminal (Max.70 mm²)
|
||
Certificate
|
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4105:2018, VDE-AR-N 4110:2018, IEC 61000-6-3, EN 50549, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA
|