After-sales Service: | Yes |
---|---|
Warranty: | 5 Years |
Nature of Source Flow: | Active Inverter |
Phase: | Three |
Output Power: | 110kw |
Certification: | SAA, CE, ROHS, ISO9001, TUV CQC SAA |
Customization: |
---|
Suppliers with verified business licenses
Type designation
|
SG8.0
RT-20
|
SG10
RT-20
|
SG12
RT-20
|
SG15
RT-20
|
SG17
RT-20
|
SG20
RT-20
|
Input (DC)
|
||||||
Min. PV input voltage
|
1100V
|
|||||
Startup input voltage
|
180 V
|
|||||
Nominal PV input voltage
|
600 V
|
|||||
MPP voltage range
|
160V~1000V
|
|||||
No. of independent MPP inputs
|
2
|
|||||
No. of independent MPP inputs
|
1 / 1
|
1 / 1
|
1 / 1
|
2 / 1
|
2 / 2
|
2 / 2
|
Max. PV input current
|
25A
|
25A
|
25A
|
37.5A
|
50A
|
50A
|
Max. DC short-circuit current
|
32A
|
32A
|
32A
|
48A
|
64A
|
64A
|
Output (AC)
|
||||||
Nominal AC power
|
8000W
|
10000W
|
12000W
|
15000W
|
17000W
|
20000W
|
Max. AC output power
|
8800VA
|
11000VA
|
13200VA
|
16500VA
|
18700VA
|
22000VA
|
Max. AC output current
|
13.3A
|
16.7A
|
20A
|
25A
|
28.3A
|
31.9A
|
Nominal AC voltage
|
3 / N / PE, 230/400 V
|
|||||
AC voltage range
|
270V~480V
|
|||||
Nominal grid frequency
|
50 Hz
|
|||||
Power factor at nominal power
|
> 0.99
|
|||||
Adjustable power factor
|
0.8 leading - 0.8 lagging
|
|||||
Feed-in phases / connection phases
|
3 / 3
|
|||||
Efficiency
|
||||||
Max. efficiency
|
98.5%
|
98.5%
|
98.5%
|
98.6%
|
98.6%
|
98.6%
|
Euro. efficiency
|
98.0 %
|
98.1 %
|
98.1%
|
98.1%
|
98.2%
|
98.2%
|
Protection
|
||||||
DC reverse connection protection
|
Yes
|
|||||
AC short circuit protection
|
Yes
|
|||||
Leakage current protection
|
Yes
|
|||||
Grid monitoring
|
Yes
|
|||||
Ground fault monitoring
|
Yes
|
|||||
DC switch
|
Yes
|
|||||
PV String current monitoring
|
Yes
|
|||||
PID recovery function
|
Yes
|
|||||
Overvoltage protection
|
DC Type II / AC Type II
|
|||||
General Data
|
||||||
Dimensions (W*H*D)
|
370*480*195 mm
|
|||||
Weight
|
17 kg
|
17 kg
|
17 kg
|
17 kg
|
20 kg
|
20 kg
|
Isolation method
|
Transformless
|
|||||
Ingress protection rating
|
IP65
|
|||||
Night power consumption
|
<1W
|
|||||
Operating ambient temperature range
|
25ºC~+60ºC
|
|||||
Allowable relative humidity range
|
0 - 100 %
|
|||||
Cooling method
|
Smart forced air cooling
|
|||||
Max. operating altitude
|
4000 m (> 2000 m derating)
|
|||||
Communication
|
RS485 / Optional: Wi-Fi, Ethernet
|
|||||
DC connection type
|
MC4
|
|||||
AC connection type
|
OT or DT
|
What's your payment terms?TT,Letter of Credit,Paypal,Western Union etc. Could you send free sample?
Your sample fee will be returned when your place next order.
Suppliers with verified business licenses