Customization: | Available |
---|---|
After-sales Service: | 10 Years |
Warranty: | 10 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Datasheet
|
Growatt PCS50
|
Growatt PCS100
|
Growatt PCS250
|
Growatt PCS500
|
AC(Grid-connected)
|
||||
Apparent power
|
55kVA
|
110kVA
|
275kVA
|
550kVA
|
Rated power
|
50KW
|
100KW
|
250KW
|
500KW
|
Rated voltage
|
400V
|
400V
|
400V
|
400V
|
Rated current
|
72A
|
144A
|
361A
|
722A
|
Voltage range
|
310V-450V
|
310V-450V
|
310V-450V
|
310V-450V
|
Rated frequency
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
Frequency range
|
45-55/55-65Hz
|
45-55/55-65Hz
|
45-55/55-65Hz
|
45-55/55-65Hz
|
THDI
|
<3%
|
<3%
|
<3%
|
<3%
|
PF
|
0.8lagging-0.8leading
|
0.8lagging-0.8leading
|
0.8lagging-0.8leading
|
0.8lagging-0.8leading
|
AC connection
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
3/PE
|
AC(off-grid)
|
||||
Apparent power
|
55kVA
|
110kVA
|
275kVA
|
550kVA
|
Rated power
|
50KW
|
100KW
|
250KW
|
500KW
|
Rated voltage
|
400V
|
400V
|
400V
|
400V
|
Rated current
|
72A
|
144A
|
361A
|
722A
|
THDU
|
≤2% linear
|
≤2% linear
|
≤2% linear
|
≤2% linear
|
Rated frequency
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
50/60Hz
|
Overload capability
|
110%-10min 120%-1min
|
110%-10min 120%-1min
|
110%-10min 120%-1min
|
110%-10min 120%-1min
|
DC(battery)
|
||||
Rated power
|
50kW
|
100kW
|
250kW
|
500kW
|
Current regulation
|
±1%
|
±1%
|
±1%
|
±1%
|
Voltage regulatoin
|
±1%
|
±1%
|
±1%
|
±1%
|
Voltage ripple
|
<3%
|
<3%
|
<3%
|
<3%
|
Current ripple
|
<2%
|
<2%
|
<2%
|
<2%
|
Rated voltage
|
600VDC
|
600VDC
|
600VDC
|
700VDC
|
Voltage range
|
500V-820V
|
500V-820V
|
500V-820V
|
600V-900V
|
Rated current
|
84A
|
167A
|
417A
|
714A
|
General Information
|
||||
Maximum efficiency
|
95.50%
|
97.10%
|
97.30%
|
98.50%
|
Protection degree
|
IP20
|
IP20
|
IP20
|
IP20
|
Noise emission
|
<65dB(A)@1m
|
<65dB(A)@1m
|
<65dB(A)@1m
|
<65dB(A)@1m
|
Environment temperature
|
-25°C...+55°C
|
-25°C...+55°C
|
-25°C...+55°C
|
-25°C...+55°C
|
Cooling
|
Forced-air
|
Forced-air
|
Forced-air
|
Forced-air
|
Relative humidity
|
0-95% non-condensing
|
0-95% non-condensing
|
0-95% non-condensing
|
0-95% non-condensing
|
Maximum altitude
|
6000m
(derate above 3000m)
|
6000m
(derate above 3000m)
|
6000m
(derate above 3000m)
|
6000m
(derate above 3000m)
|
Dimension(W/H/D)
|
600/1630/800mm
|
1100/1890/850mm
|
1600/2080/850mm
|
1200/1900/800mm
|
Weight
|
450kg
|
820kg
|
1465kg
|
900Kg
|
Build-in transformer
|
Yes
|
Yes
|
Yes
|
NO
|
Transfer between on/off grid
|
Manual(default) Automatic(optional)
≤10ms
|
Manual(default) Automatic(optional)
≤10ms
|
Manual(default) Automatic(optional)
≤10ms
|
Manual(default) Automatic(optional)
≤10ms
|
Communication
|
||||
Display
|
Touch screen
|
Touch screen
|
Touch screen
|
Touch screen
|
Communication interface
|
RS485/CAN
|
RS485/CAN
|
RS485/CAN
|
RS485/CAN
|