Model
|
Solis-25K-5G
|
Solis-30K-5G
|
Solis-33K-5G
|
Solis-36K-5G
|
Input DC
|
||||
Max. DC input power(kW):
|
33
|
39
|
43
|
47
|
Max. DC input voltage(V):
|
1100
|
1100
|
1100
|
1100
|
Start-up voltage(V):
|
180
|
180
|
180
|
180
|
MPPT voltage range(V):
|
200-1000
|
200-1000
|
200-1000
|
200-1000
|
Max. input current(A):
|
26+26+26
|
26+26+26
|
26+26+26
|
26+26+26+26
|
MPPT number:
|
3
|
3
|
3
|
4
|
Max input strings number:
|
A:2; B:2; C:2
|
A:2; B:2; C:2
|
A:2; B:2; C:2
|
A:2; B:2; C:2; D:2
|
Max. Short Circuit current for each MPPT:
|
39+39+39
|
39+39+39
|
39+39+39
|
39+39+39+39
|
Output AC
|
||||
Rated output power(kW):
|
25
|
30
|
33
|
36
|
Max. apparent output power(kVA):
|
27.5
|
33
|
36.3
|
39.6
|
Max. output power(kW):
|
27.5
|
33
|
36.3
|
39.6
|
Rated grid voltage(V):
|
400
|
400
|
400
|
400
|
Rated grid frequency(Hz):
|
50/60
|
50/60
|
50/60
|
50/60
|
Grid frequency range(Hz):
|
47-52 or 57-62
|
47-52 or 57-62
|
47-52 or 57-62
|
47-52 or 57-62
|
Operation phase:
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
Rated grid output current(A):
|
36
|
43.3
|
47.6
|
51.9
|
Max. output current(A):
|
41.8
|
50.2
|
55.1
|
60.2
|
THDi (at rated output power):
|
<3%
|
<3%
|
<3%
|
<3%
|
DC injection current(mA):
|
<0.5%In
|
<0.5%In
|
<0.5%In
|
<0.5%In
|
Power Factor (at rated output power):
|
0.8leading ... 0.8lagging
|
|||
Efficiency
|
||||
Max.efficiency:
|
98.8%
|
98.8%
|
98.8%
|
98.8%
|
EU efficiency:
|
98.3%
|
98.3%
|
98.3%
|
98.3%
|
MPPT efficiency:
|
>99.5%
|
>99.5%
|
>99.5%
|
>99.5%
|
Protection
|
||||
DC reverse-polarity protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Short circuit protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Output over current protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Output over voltage protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Insulation resistance monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Residual current detection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Surge protection:
|
DC Type II/ AC Type II
|
DC Type II/ AC Type II
|
DC Type II/ AC Type II
|
DC Type II/ AC Type II
|
Islanding protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Temperature protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Integrated DC switch:
|
Optional
|
Optional
|
Optional
|
Optional
|
Strings monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Anti-PID:
|
Optional
|
Optional
|
Optional
|
Optional
|
General Data
|
||||
Dimensions(mm):
|
647W*629H*252D
|
|||
Weight(kg):
|
45
|
45
|
45
|
45
|
Topology:
|
Transformerless
|
|||
Self consumption (night):
|
<1W(Night)
|
|||
Ingress protection:
|
Ip65
|
|||
Noise emission(typical):
|
<30 dBA
|
|||
Cooling concept:
|
Natural convection
|
|||
Max.operation altitude::
|
4000m
|
|||
Designed lifetime:
|
>20years
|
|||
Relative humidity:
|
0~100%
|
|||
Operating ambient temperature range:
|
-25~60ºC
|
|||
Grid connection standard:
|
EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018
|
|||
Safty/EMC standard:
|
IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3
|
|||
Features
|
||||
DC connection:
|
MC4
|
|||
AC connection:
|
Terminal coonectors
|
|||
Display:
|
LCD,2*20 Z.
|
|||
Communication connections:
|
4 pins RS485 connector
|
|||
Monitoring:
|
WiFi or GPRS
|
|||
Warranty:
|
5/10/15/20 Years
|
Model
|
Solis-40K-5G
|
Solis-40K-HV-5G
|
Solis-50K-HV-5G
|
Input DC
|
|||
Max. DC input power(kW):
|
52
|
52
|
65
|
Max. DC input voltage(V) :
|
1100
|
1100
|
1100
|
Start-up voltage(V) :
|
180
|
180
|
180
|
MPPT voltage range(V) :
|
200-1000
|
200-1000
|
200-1000
|
Max. input current(A) :
|
26+26+26+26
|
26+26+26+26
|
26+26+26+26
|
MPPT number :
|
4
|
4
|
4
|
Max input strings number :
|
A:2; B:2; C:2; D:2
|
A:2; B:2; C:2; D:2
|
A:2; B:2; C:2; D:2
|
Max. Short Circuit current for each MPPT :
|
39+39+39+39
|
39+39+39+39
|
39+39+39+39
|
Output AC
|
|||
Rated output power(kW):
|
40
|
40
|
50
|
Max. apparent output power(kVA) :
|
44
|
44
|
55
|
Max. output power(kW) :
|
44
|
44
|
55
|
Rated grid voltage(V) :
|
400
|
480
|
480
|
Rated grid frequency(Hz) :
|
50/60
|
50/60
|
50/60
|
Grid frequency range(Hz) :
|
47-52 or 57-62
|
47-52 or 57-62
|
47-52 or 57-62
|
Operation phase :
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
Rated grid output current(A) :
|
57.7
|
48.1
|
60.1
|
Max. output current(A) :
|
66.9
|
53
|
66.2
|
THDi (at rated output power) :
|
<3%
|
<3%
|
<3%
|
DC injection current(mA) :
|
<0.5%In
|
<0.5%In
|
<0.5%In
|
Power Factor (at rated output power) :
|
0.8leading ... 0.8lagging
|
||
Efficiency
|
|||
Max.efficiency:
|
98.8%
|
98.8%
|
98.8%
|
EU efficiency:
|
98.3%
|
98.3%
|
98.3%
|
MPPT efficiency :
|
>99.5%
|
>99.5%
|
>99.5%
|
Protection
|
|||
DC reverse-polarity protection:
|
Yes
|
Yes
|
Yes
|
Short circuit protection :
|
Yes
|
Yes
|
Yes
|
Output over current protection :
|
Yes
|
Yes
|
Yes
|
Output over voltage protection :
|
Yes
|
Yes
|
Yes
|
Insulation resistance monitoring :
|
Yes
|
Yes
|
Yes
|
Residual current detection :
|
Yes
|
Yes
|
Yes
|
Surge protection :
|
DC Type II/ AC Type II
|
DC Type II/ AC Type II
|
DC Type II/ AC Type II
|
Islanding protection :
|
Yes
|
Yes
|
Yes
|
Temperature protection :
|
Yes
|
Yes
|
Yes
|
Integrated DC switch :
|
Optional
|
Optional
|
Optional
|
Anti-PID:
|
Optional
|
Optional
|
Optional
|
General Data
|
|||
Dimensions(mm):
|
647W*629H*252D
|
||
Weight(kg) :
|
45
|
45
|
45
|
Topology :
|
Transformerless
|
||
Self consumption (night) :
|
<1W(Night)
|
||
Ingress protection :
|
Ip65
|
||
Noise emission{typical} :
|
<30 dBA
|
||
Cooling concept :
|
Natural convection
|
||
Max.operation altitude :
|
4000m
|
||
Designed lifetime :
|
>20years
|
||
Relative humidity :
|
0~100%
|
||
Operating ambient temperature range :
|
-25~60ºC
|
||
Grid connection standard :
|
EN50438, G99, AS4777, VDE0126-1-1, IEC61727,VDE4105(2018
|
||
Safty/EMC standard:
|
IEC62109-1/-2, AS3100, EN61000-6-1, EN61000-6-3
|
||
Features
|
|||
DC connection:
|
MC4
|
||
AC connection :
|
Terminal coonectors
|
||
Display :
|
LCD,2×20 Z.
|
||
Communication connections :
|
4 pins RS485 connector
|
||
Monitoring :
|
WiFi or GPRS
|
||
Warranty :
|
5/10/15/20 Years
|
Model
|
Solis-80K-5G
|
Solis-80K-HV-5G
|
Solis-90K-HV-5G
|
Solis-100K-HV-5G
|
Solis-110K-HV-5G
|
Input DC
|
|||||
Max. DC input power(kW):
|
104
|
104
|
117
|
120
|
132
|
Max. DC input voltage(V):
|
1100
|
1100
|
1100
|
1100
|
1100
|
Start-up voltage(V):
|
200
|
200
|
180
|
180
|
180
|
MPPT voltage range(V):
|
180-1000
|
180-1000
|
200-1000
|
200-1000
|
200-1000
|
Max. input current(A):
|
26
|
26
|
26
|
26
|
26
|
MPPT number:
|
8
|
8
|
9
|
9
|
10
|
Max input strings number:
|
16
|
16
|
2
|
2
|
2
|
Max. Short Circuit current for each MPPT:
|
40.6
|
40.6
|
40.6
|
40.6
|
40.6
|
Output AC
|
|||||
Rated output power(kW):
|
80
|
80
|
90
|
100
|
110
|
Max. apparent output power(kVA):
|
88
|
88
|
99
|
110
|
121
|
Max. output power(kW):
|
88
|
88
|
99
|
110
|
121
|
Rated grid voltage(V):
|
400
|
480
|
480
|
480
|
480
|
Operation phase:
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
3/N/PE
|
Max. output current(A):
|
133.7
|
105.9
|
119.1
|
132.3
|
129.4
|
THDi (at rated output power):
|
<2%
|
<2%
|
<2%
|
<2%
|
<2%
|
Power Factor (at rated output power):
|
0.8leading ... 0.8lagging
|
||||
Efficiency
|
|||||
Max.efficiency:
|
99%
|
99%
|
99%
|
99%
|
99%
|
EU efficiency:
|
98.4%
|
98.4%
|
98.4%
|
98.4%
|
98.4%
|
MPPT efficiency:
|
>99.5%
|
>99.5%
|
>99.5%
|
>99.5%
|
>99.5%
|
Protection
|
|||||
Anti-islanding protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
DC reverse-polarity protection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Insulation resistance monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Residual current detection:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
DC Surge protection:
|
Type replaceable
|
Type replaceable
|
Type replaceable
|
Type replaceable
|
Type replaceable
|
AC Surge protection:
|
Type
|
Yes
|
Yes
|
Yes
|
Yes
|
Grid monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Strings Monitoring:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
I/V Curve scanning:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Anti-PID function:
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
AFCI fuction:
|
Optional
|
Optional
|
Optional
|
Optional
|
Optional
|
General Data
|
|||||
Dimensins(mm):
|
1050W*567H*286.5D
|
||||
Weight(kg):
|
75
|
||||
Topology:
|
Transformerless
|
||||
Self consumption (night):
|
<2W(Night)
|
||||
Ingress protection:
|
Ip65
|
||||
Noise emission(typical):
|
<55 dBA
|
||||
Cooling concept:
|
Fan cooling
|
||||
Max.operation altitude::
|
4000m(>2000m derating)
|
||||
Designed lifetime:
|
>20years
|
||||
Designed lifetime:
|
0~100%
|
||||
Operating ambient temperature range:
|
-25~60ºC
|
||||
Grid connection standard:
|
EN50549, G99, AS4777, VDE0126-1-1, IEC61727, VDE4105
|
||||
Safty/EMC standard:
|
IEC62109-1/-2, NB/T 32004,EN61000-6-1, EN61000-6-3
|
||||
Features
|
|||||
DC switch:
|
Integrated
|
||||
DC connection:
|
MC4
|
||||
AC connection:
|
OT Terminal connectors
|
||||
DRM function:
|
Yes
|
||||
Display:
|
LCD,2*20 Z.
|
||||
OTA update:
|
Yes
|
||||
Communication connections:
|
1*4pin RS485,2*RJ45,1*DRM
|
||||
Communication:
|
RS485/ WLAN(provide);PLC/Wifi/GPRS(optional)
|
||||
Monitoring:
|
WiFi or GPRS
|
||||
Warranty:
|
5/10/15/20 Years
|